+39 0331 1693557 inti@intisrl.it

INTIMAC

OUR EXPERIENCE AT YOUR SERVICE

Production and packaging machinery for the pharmaceutical, chemical and cosmetic industry

Autoclaves/Sterilizing Ovens/Freeze Dryers

We carry out the complete revamping of the machines

Download of all our available used machinery

Autoclaves/Sterilizing Ovens/Freeze Dryers [6]

DE LAMA Autoclave DE LAMA DLOV
Autoclave DE LAMA DLOV
IT121
DE LAMA
DLOV
1998

Double door autoclave De Lama model DLOV.
Year of manufacturing: 1998.
Useful capacity: 4990 liters.
Supply voltage: 380 V - 50 Hz Tri-phase.
Installed power: 6 kW.
Maximum working pressure: 2.5 bar.
Maximum working temperature: 138.2 C °.
Installed cycles: A sterilization + drying B for vials C For closed containers I test cold vacuum machine J sterilization air filter in situ.

more info
DE LAMA Sterilizing Oven DE LAMA DLST/L
Sterilizing Oven DE LAMA DLST/L
IT122
DE LAMA
DLST/L
1998

Double door depyrogenation owen De Lama model DLST/L
Year of manufacturing 1998
Useful capacity 5440 liters
Supply voltage 380 V - 50 Hz Tri - phase
Installed power 157 kW
Maximum working temperature 250 C °

more info
GETINGE Autoclave Getinge sterilization AB model GEC 900 X1450X1350-2
Autoclave Getinge sterilization AB model GEC 900 X1450X1350-2
IT341
GETINGE
GEC 900 X1450X1350-2
2007

Autoclave Getinge sterilization AB model GEC 900 X1450X1350-2
Dimensions L x B x H: 2600 x 1700 x 2500 mm
Internal dimensions: B 890 x D 1000 x H 1450 mm
Steam: 161 kg
Steam process: Use 3 kg; peak/min. 0.1 kg; 2.7 - 3.0 bar
Water process: use 200 liters; peak/min. 40 liters; 4.0 - 6.0 bar
Cooling water: 2110 litres; peak/min. 150 litres; 2.0-3.0 bar
Air: use 0.5 Nm3; peak/min. 0.2 Nm3; 6.0-8.0 bar
Air process: use 4.8 Nm3; peak/min. 1.5 Nm3; 4 . 0-6.0 bar
Cooling water return: 2110 litres; peak/min. 150 litres
Drainage: peak/min. 60
Three-phase with 400 Volt voltage; 4.3 kW
Frequency: 50 Hz
Recommended fuse: 25 Ampere
Rated power: 4,3 Kw
Rated current: 8.3 A
Short circuit current: 6 ka
Maximum single load: 7,8 A
Emission of heat:
Loading area: 1.1 Kw
Discharge zone: 1.1 Kw
Service area: 4.5 Kw
Sound level: < 70 dba

more info
GETINGE Autoclave Getinge sterilization AB model GE 672x920x1350-2
Autoclave Getinge sterilization AB model GE 672x920x1350-2
IT342
GETINGE
GE 672X920X1350-2
2006

Autoclave Getinge sterilization AB model GE 672x920x1350-2
Steam (non-process): 9 kg; peak/min. 0.9 kg; 2.7-3.0 bar
Steam process: Use 15 kg; peak/min. 0.9 kg; 1.5-2.0 bar
Water pump: use 30 liters; peak/min. 10 liters; 4.0-6.0 bar
Cooling water: 280 liters; peak/min. 32 liters; 2.0-3.0 bar
Air: usage 0.4 Nm3; peak / min. 0,2 Nm3; 6.0-7.0 bar
Air process: usage 3.4 Nm3; peak/min. 0,4 Nm3; 4.0-5.0 bar
Cooling water return: 280 liters; peak/min. 32 litres
Drainage: peak / min. 20
Three-phase with voltage 400 volts; 4,3 kW
Frequency: 50Hz
Recommended fuse: 20 Ampere
Rated power: 3 Kw
Rated current: 7A
Short circuit current: 6 kA
Maximum single load: 6 A
Heat emission:
Load area: 0.5 Kw
Discharge area: 0.5 Kw
Service Area: 2.6 Kw
Sound level: < 70 dBa

more info
DE LAMA Autoclave DE LAMA DLOV PLSA
Autoclave DE LAMA DLOV PLSA
IT346
DE LAMA
DLOV PLSA
1999

Supply voltage: 380 V, 50 Hz, three phase
Installed power: 4,5 kW
Maximum working pressure: 2.5 bar, 250 kPa
Maximum operating temperature: 138.2 °c, 411.2 K
Useful capacity: 1000 liters
Internal dimensions: height 1000 mm, width 800 mm, depth 1250 mm.
External dimensions: height 2150 mm, width 1700 mm, depth 1800 mm.
Theoretical empty weight: 2100 kg
Theoretical weight at hydraulic testing: 3100 kg
Theoretical working weight (excluding product): 2150 kg
Water supply vacuum pump:
connection size: Ø ½ "" GAS UNI338
Minimum pressure: 1.5 bar
Maximum temperature: 20 °C
Maximum required flow rate: 0.9 m3 / h (15 liters per minute)
Indicative consumption per cycle: 750 litres
Water supply for cooling:
connection size: Ø ½ "" GAS
Minimum pressure: 2.5 bar
Maximum temperature: 20 °C
Maximum required flow rate: 0.72 m3 / h (12 liters per minute)
Clean dry saturated steam:
connection size: Ø ¾ "" DN 20
maximum pressure: 3.5 bar, minimum pressure: 2.5 bar
maximum capacity required: 90 Kg / h
indicative consumption cycle: 68 Kg
industrial steam for interlocks:
connection size: Ø ½ "" GAS UNI338
maximum pressure: 3.5 bar, minimum pressure: 2.5 bar
maximum capacity required: 45 Kg / h
indicative consumption cycle: 34 Kg
sterile compressed air room entrance:
connection size: Ø ½ "" GAS UNI338
maximum pressure: 3.5 bar, minimum pressure: 2.5 bar
Maximum capacity required: 50 m3/h (840 liters per minute)
indicative consumption cycle: 16.800 liters
compressed air tools:
for controls – connection dimensions: Ø ½ "" GAS UNI338
maximum pressure: 7 bar, minimum pressure: 6 bar
Maximum capacity required: 5 m3 / h (83 litres per minute)
Electrical power installed:
system: three phase + ground + neutral
voltage: 380V-frequency: 50Hz
power: 3.55 kW
superpres discharge. Chamber safety valve:
connection size: 1 ½ "" GAS F UNI338
Maximum temperature: 140 °C
superpres discharge. Safety valve intercap.:
connection size: 1 " GAS F UNI338
Maximum temperature: 140 °C
Vacuum pump discharge-total discharge:
connection size: 1 ½ "" GAS UNI338
Maximum temperature: 110 °C

more info
ICP Sterilizing Oven ICP DS 100
Sterilizing Oven ICP DS 100
IT347
ICP
DS 100
1996

The dry sterilizer oven DS 100 is used for the sterilization and depyrogenization of empty glassware or other glass or stainless steel packaging or containment material so that it can be introduced into a sterile room.
After the sterilization cycle, the material is therefore discharged from the passage door of the sterile rooms. Being the filters placed at the exit of the sterilization Chamber, of the absolute type filters with cold efficiency of 99.998 DOP method, during sterilization, the air circulating inside the trolleys is air in class 100. The filters used for this purpose are filters that continuously withstand a temperature of 240 degrees centigrade and therefore allow both dry sterilization and depyrogenation.
During all stages of treatment, inside the furnace, the pressure is constantly maintained positive with respect to the external environment. After the automatic sterilization cycle, the shutters all close to isolate the oven from the outside while the ventilation continues to work to maintain the internal overpressure ensuring that the material is not contaminated.
Sterilization time: 60 min for temperature 220 C while 75 min for temperature 200 C.
Cooling time to be set around 120 min.
See for the use of timers the attached instructions taking into account to always set the MODE "A" and the value in MIN. The cooling time should be selected according to the experience resulting from the type of load used and the temperature of the sucked air.

more info

CONTACTS

INTIMAC s.r.l.

Via XXV Aprile, 8

21054 Fagnano Olona (VA)

Italia

Tel. +39 0331 1693557

email: inti@intisrl.it