Preparation vessel for sterile products Praminox
Year: 1997
Temperature: °C 152
Coat side: bar/s 4/vacuum
Hydrostatic pressure: bar/s 4/vacuum
Pressure:bar/s 6/7
Adjustment capacity: from 0 ÷ 2800 RPM
(a) RPM with turbine = 1400 RPM = 25 Hz
(b) RPM with propeller = 2800 RPM = 50 Hz
Preparation vessel for liquids 75L Giusti
Capacity: 75 litres
Maximum internal pressure: atmospheric
Maximum external pressure: 3. 3
Minimum internal pressure: atmospheric
Minimum external pressure: atmospheric
Internal pressure test: water filling
External pressure test: 5. 0
Internal working pressure: atmospheric
External working pressure: 3. 0
Internal and external temperature: 150 °C
TYPE: MOBILES TANK
WORKING PRESSURE: 2 BAR – 1 BAR
TEST PRESSURE: 3BAR
MAXIMUM TEMPERATURE: 120° C
CAPACITY : 100 L
Resolute™ Chromatography column is suited for process purification in the BioPharmaceutical industry.
Operating pressure 3 bar g
max allowable pressure 4,2 bar g
test pressure 6,0 bar g
minimum pressure -1,0 bar g
test pressure date 2010
design temperature 2-30°C
Weight (empty) 351 kg
Volume 28.3 -84.9 litres
preparation vessel for sterile with 1 chamber
volume 280 l
design pressure -1/4.1 bar (g)
test pressure 8.7 bar (g)
design temp. 80°C
burst disc 4.1 bar (g)
weight waterfilled 550 kg
weight empty 300 kg
purpose slurry
fluide group 2
category III
pharmaceutical storage and preparation vessel for sterile with double jacket
vessel jacket
fluid group 2 2
capacity V 295 Lt 23 Lt
design pressure PS -1 / +3 bar (g) +3 bar (g)
design temperature TS +143,7 °C +143,7 °C
Hydraulic test pressure 4,9 bar (g) 4,9 bar (g)
Hydraulic test date 15/10/2010
total empty weight 320kg
pharmaceutical storage and preparation vessel for sterile with double jacket
vessel jacket
fluid group 2 2
capacity V 441 34
design pressure PS -1/+4 bar (g) -1/+4 bar (g)
design temperature TS 153°C 153°C
Hydraulic test pressure 7.2 bar (g) 7.2 bar (g)
PED category III
Resolute™ Chromatography column is suited for process purification in the BioPharmaceutical industry.
Design code PED 97/23/EC
PED Category CAT 1 Module A
Operating pressure 3 bar g
max allowable pressure 4.2 bar g
test pressure 6.0 bar g
minimum pressure -1.0 bar g
design temperature 2-30°C
Weight (empty) 310 kg
Volume 19.6 -59.9 litres
Resolute™ Chromatography column is suited for process purification in the BioPharmaceutical industry.
Design code PED 97/23/EC
PED Category CAT 1 Module A
Operating pressure 3 bar g
max allowable pressure 4.2 bar g
test pressure 6.0 bar g
minimum pressure -1.0 bar g
design temperature 2-30°C
Weight (empty) 351 kg
Volume 28.3 -84.9 litres
manufacturing number 5903-8250
Equipment: Reactor of 250 L
maximum allowable pressure C-I (bar) 3.5
maximum allowable pressure C-II (bar) n/A
max temperature permissible (° C) 150
temperature min. permissible (° C) 3
total volume (I.) 318
Group 2
Category N / A
Module A
pharmaceutical storage and preparation vessel for sterile
vessel jacket
fluid group 2 -
capacity V 200 Lt -
design pressure PS -1 / +4 bar (g) -
design temperature TS +152,0 °C -
Hydraulic test pressure 7.3 bar (g) -
Hydraulic test date 17/11/2010
Total empty weight 140kg
PED Category II
Serial number PR800 0096
description : 1250 litre liquid reactor with top agitator.
Technical data : dialysis fluidity : 15,7 - 17,7 % v/v 10/061
Vessels/Tanks T&C STAINLESS - 60 L
60 L Wessel Mawp 50 - Wessel Maewp 15 - MBMT -20 - Top head thk 7GA - Bom head thk 7GA Jacket Mawp 150 - Jacket Maewp 15 Mbmt -20 Material 316 L PSIG AT 300 °F AT 50 SHELL THK7GA PSIG AT 300 °FAT 150 SHELL THK 14GA Material 304 L
Via XXV Aprile, 8
21054 Fagnano Olona (VA)
Italia
Tel. +39 0331 1693557