We carry out the complete revamping of the machines

22F120
ROMACO
Macofar Tipo MT8
2008
ROMACO

22F120 Matr. N1C1
MACOFAR ROMACO DEPYROGENATION TUNNEL T600 (2008)
Technical data
Max height of vials 180 mm
Long conveyor belt 550 mm
Hepa filter measure inlet zone 1 filter 610 x 610 x 292 cm
Hepa filter measure sterilization zone 1 filter 610 x 792 x 292 cm
Hepa filter measure Cooling zone 1 filter 610 x 914 x 292 cm
Long sterilization chamber 850 mm
Long cooling chamber 1000 mm
Air class inlet and outlet area Specific reference filters
Sterilization air max temperature 350 C °
Tunnel exit road temperature 35 C °
Inlet air flow 800 Nm3 / h
Air flow sterilization zone 1170 Nm3 / h
Cooling zone air flow 1380 Nm3 / h
Laminar flow velocity inlet zone 0.5 m / second
Laminar flow speed sterilization zone 0.7 m / second
Laminar flow velocity cooling zone 0.7 m / second
Power installed in the resistors 32 Kw
Power installed to the conveyor 0.2 Kw
Power installed to the fans 5.5 Kw
Total installed power 39 Kw
Standard voltage 380 V - 50 Hz
Tunnel length 2860 mm
Tunnel depth 1820 mm
Tunnel height 2650 mm
Electrical panel length 1200 mm
Electric panel depth 500 mm
Electric panel height 2000 mm
Net weight of the board 300 Kg
Sterilization efficiency 125 Kg of glass / h
CONSUMPTION
Electric energy Electric power Absorbed Kw 39
Intake air Capacity: 900 m3 / h at 1420 mm H2O
Water Cooling equipment 400 L / H at 15 C ° pressure 2-3 bar

INTIMAC, OUR EXPERIENCE AT YOUR SERVICE

We help you selecting the most suitable machine to your requirements, thanks to a thirty years’ experience in the pharmaceutical and cosmetic industry and a wide range of machinery in a more than 5,000 square meters store.

CONTACTS

INTIMAC s.r.l.

Via XXV Aprile, 8

21054 Fagnano Olona (VA)

Italia

Tel. +39 0331 1693557

email: inti@intisrl.it

TRADEMARKS